Videx VX2200 Guida alla Risoluzione dei Problemi Pagina 49

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 68
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 48
PAGE 49 of 68 VX2200 TECHNICAL MANUAL VER1.5
TROUBLE SHOOTING GUIDE
PROBLEM FOUND
POSSIBLE CAUSE POSSIBLE SOLUTION
The system has power but the front panel does
not turn on.
1. Interruption or short circuit of the 13Vdc
output on PSU to the outdoor station;
2. PSU defective or fuse blown.
1. Check the GND and +13V connections
on PSU and on panel, then check the
protection fuse on the output of PSU and
change it if necessary;
2. Check PSU output with and without load.
Front panel display shows “ERROR” and the
unit makes acoustic intermittent signals at
intervals of approx. 2 seconds.
1. Probable short circuit on the BUS and
“L” line;
2. Reversion of polarity on the BUS
connection of a phone, videophone or
accessory;
3. Panel programmed as “Slave” when it
should be as “Master”.
1. Check the BUS connections.
2. Check the polarity of the devices
connected.
3. Configure the device as ”Master”
The system, at the moment of the call, is not
able to let the extension ring, the front panel
makes acoustic signals of line engaged and the
display shows “Error”.
1. The phone or videophone called is not
correctly connected;
2. The cable size (BUS) is to small;
3. The address programmed on the dip-
switch (of the phone, videophone or
accessory) does not correspond to that
called;
4. The concierge (if present in the system)
has been left in programming mode.
1. Check the connection of the BUS
2. Double or increase cable size;
3. Check that the address associated to the
call corresponds to that programmed on
the dip-switch of the phone (videophone
or accessory);
4. Remove concierge from programming
mode.
The outdoor station makes the call correctly,
but when the user answers, the communication
is cut off.
The cable size is too small.
Double or increase cable size
During the conversation, when the door is
opened, the communication is cut off.
The cable size is too small.
Double or increase cable size
The calls goes through, but the conversation is
one-way only.
The supplying voltage on the outdoor station is
too low (under 10.5V).
Increase the supply cable size (GND & 13V).
Check voltage output on PSU and adjust if
necessary.
The audio level of conversation is too low. The levels of the conversation volumes in both
directions are not appropriately adjusted or
balanced.
Adjust on the outdoor station trimmers for
microphone and loudspeaker so as to have the
best levels without oscillations (Larsen effect)
The audio level is at its limit or oscillates
(Larsen effect).
The “Balance” trimmer (outdoor station) is not
appropriately set and/or the conversation
volumes are programmed to high.
Adjust on the outdoor station the “balance”
trimmer until the problem is solved and/or
lower the volumes of the microphone and
loudspeaker.
The door release is not working. 1. Lock defective;
2. Connection wrong or interrupted;
3. Cable size to small;
4. Lock PSU faulty.
1. Change the lock;
2. Check connection continuity;
3. Increase cable size;
4. Check power supply output;
The local floor call does not work. 1. Call push button defective;
2. Connection wrong or interrupted.
1. Check defect;
2. Check connection.
The internal video stations do not turn on. 1. Art.893N power supply defective or in
protection;
2. Art.893N is not operated by the outdoor
station during the call (SL terminal);
3. Connection wrong or interrupted.
1. Check 893 with and without a load;
2. “-C” terminal of art.893N not correctly
connected to the “SL” terminal of the
outdoor station;
3. Check the continuity of the connection
between the monitor supplying wires and
the videophones interested.
The internal video stations turn on, but the
image does not appear.
1. Art.830NC video camera not supplied or
defective;
2. Connection of the V1-V2 signals
interrupted or wrong.
3. Video dip-switches on monitor or
jumpers on camera incorrectly positioned
1. Check and/or change art 830NC;
2. Check connection continuity.
3. Check all dip-switches and jumpers.
The internal video station turns on but the
quality of the image is bad or reflected.
1. Signal V1 or V2 not connected or in short
circuit;
2. V1 & V2 signals inverted;
3. Closing resistances are missing at the end
of the BUS video.
4. Dip-switches or jumpers on monitor or
camera not correctly positioned
1. Check the continuity of the connection
and the isolation to the ground;
2. Check and in case invert the connections;
3. Check and in case apply the closing
resistances on the BUS video.
4. Check dip-switches and jumpers.
Vedere la pagina 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 67 68

Commenti su questo manuale

Nessun commento