PAGE 18 of 68 VX2200 TECHNICAL MANUAL VER1.5
TIME CLOCK
The 701T is a BST/GMT time clock with 6 programmable on/off
periods and two modes of operation. The first mode being a
standard time clock mode whereby the dry contact relay output
triggers for the length of an on/off period. The second mode is
known as the trade button mode and only operates the relay when
the trade input is triggered and during an active on/off period. The
relay would then stay energised for a programmed time (01-99
seconds).
CONNECTION FUNCTION
+ 12Vdc power supply input
- 0V power supply connection
TR Trade button input (Shorts to 0V)
C Common connection of dry contact relay output
NO Normally open connection of dry contact relay output
NC Normally closed connection of dry contact relay output
JUMPERS
The jumper in the top right selects the time clocks mode of operation.
A = TRADE BUTTON MODE
B = TIME CLOCK MODE
The jumper in the middle Enables/Disables automatic BST/GMT time correction
A = AUTOMATIC ADJUSTMENT DISABLED
B = AUTOMATIC ADJUSTMENT ENABLED
The time clock includes a battery to maintain the time while the time clock isn’t powered.
The battery should maintain the time and settings for a minimum of 3 months.
ON = BATTERY ENABLED
OFF = BATTERY DISABLED (Should be moved to ON when installed)
TECHNICAL SPECIFICATION
Supply Voltage : 12V DC or 12V AC
Standby Current (Relay off) : 47mA
Standby Current (Relay on) : 67mA
Battery backup : Min. 3 Months
Relay contacts (Dry contact) : 3A @ 24V DC
3A @ 120V AC
On/Off times available : Six
: ON/OFF period 1 will switch off at the off time for that period
regardless of manual override.
: ON/OFF period 2-6 will Not
switch off at the off time for that period if
manual override is pressed.
Trade mode relay time : From 1 second to 99 seconds
Dimensions : 110mm x 70mm x 30mm
Commenti su questo manuale