PAGE 44 of 68 VX2200 TECHNICAL MANUAL VER1.5
CABLE GUIDE
The following table outlines the maximum resistance allowed from furthest point to furthest point.
Cable sizes
Distance
up to
(-) (L) (V1)* (V2)*
Signals
Max. Resistence
(-)* (+20)*
Signals
Max. Resistence
100m 0.3mmsq AWG22
7.5 Ohms
0.6mmsq AWG19
5 Ohms
200m 0.6mmsq AWG19 1.0mmsq AWG17
350m 1.0mmsq AWG17 1.5mmsq AWG15
500m 1.5mmsq AWG15
Supply cables ( power supply outdoor station): they must have a minimum size of 1.0mmsq (AWG17)
or more (Depending on the distance between the supply’s and the outdoor station) with maximum resistance
of 1.5 Ohm
per core.
Door panel earth: All vandal resistant door panels must be earthed (Earth studs will be found on all vandal
resistant panels and back boxes). To accomadate this we suggest running a 2.5mm
2
earth cable from the
panel to the control cabinet where it can be connected to the cabinets earth.
Art.3161 Art.3162 Art.3171 Art.3172
MIN. CORES <50m <100m <200m <300m <400m <500m
2 4 Pair CW1308
CAT5
4 Pair CW1308
4 Core 0.5mm
2
YY
CAT5
6 Pair CW1308
4 Core 0.75mm
2
YY
6 Pair CW1308
4 Core 1.0mm
2
YY
4 Core
1.5mm
2
YY
4 Core
2.5mm
2
YY
Art.3176
3 4 Pair CW1308
CAT5
6 Pair CW1308
12 Core 0.5mm
2
YY
6 Pair CW1308
12 Core 0.5mm
2
YY
10 Pair CW1308
12 Core 0.5mm
2
YY
7 Core
1.5mm
2
YY
7 Core
2.5mm
2
YY
Art.5178 Art.VR5178
4 4 Pair CW1308
CAT5
4 Pair CW1308
12 Core 0.5mm
2
YY
6 Pair CW1308
12 Core 0.5mm
2
YY
10 Pair CW1308
12 Core 0.5mm
2
YY
12 Core
1.0mm
2
YY
Not
recommended
Art.3371 Art.3471
MIN. CORES <50m <100m <200m <300m <400m <500m
Balanced = 6 4 Pair CW1308
CAT5
6 Pair CW1308
or
12 Core 0.5mm
2
YY
10 Pair CW1308
or
12 Core 0.5mm
2
YY
12 Core 0.5mm
YY
Not
recommended
Not
recommended
Coax = 4 + Coax 4 Pair CW1308 or
CAT5
+ RG59 (BC)
6 Pair CW1308
or
12 Core 0.5mm
2
YY
+ RG59 (BC)
6 Pair CW1308
or
12 Core 0.5mm
2
YY
+ RG59 (BC)
12 Core 0.5mm
YY
+ RG11 (BC)
12 Core
0.75mm
2
YY
+ RG11 (BC)
12 Core
1.0mm
2
YY
+ RG11 (BC)
Art.3376 Art.3476
Balanced = 7 4 Pair CW1308 6 Pair CW1308
or
12 Core 0.5mm
2
YY
10 Pair CW1308
or
12 Core 0.5mm
2
YY
12 Core 0.5mm
YY
Not
recommended
Not
recommended
Coax = 5 + Coax 4 Pair CW1308
+ RG59 (BC)
6 Pair CW1308
or
12 Core 0.5mm
2
YY
+ RG59 (BC)
6 Pair CW1308
or
12 Core 0.5mm
2
YY
+ RG59 (BC)
12 Core 0.5mm
YY
+ RG11 (BC)
12 Core
0.75mm
2
YY
+ RG11 (BC)
12
Core1.0mm
2
YY
+ RG11 (BC)
Art.5476 Art.5478 Art.SL5478 Art.VR5478 Art.3678
Balanced = 8 6 Pair CW1308 10 Pair CW1308
or
12 Core 0.5mm
2
YY
12 Core 0.5mm
YY
Not
recommended
Not
recommended
Not
recommended
Coax = 7 + Coax 6 Pair CW1308
+ RG59 (BC)
10 Pair CW1308
or
12 Core 0.5mm
2
YY
+ RG59 (BC)
12 Core 0.5mm
YY
+ RG59 (BC)
12 Core
0.75mm
2
YY
+ RG11 (BC)
12 Core
1.0mm
2
YY
+ RG11 (BC)
12 Core
1.5mm
2
YY
+ RG11 (BC)
Commenti su questo manuale