PAGE 31 of 68 VX2200 TECHNICAL MANUAL VER1.5
PROGRAMMING NUMBER OF RINGS (FACTORY SET 6 RINGS)
Press and hold “
” (for approx 10 seconds) until the unit emits a beep.
Press “
” as many times as the number of rings required (i.e. 6 presses = 6 rings with a maximum
of 9 rings)
Once the number of rings required has been reached, wait 3 seconds for the exit beep.
The new value is now stored.
PROGRAMMING THE PRIVACY DURATION (FACTORY SET WITH OUT TIMEOUT)
Press and hold “
” (for approx 10 seconds) until the unit emits a beep.
Press “
” again to set the privacy duration. Each time the button is pressed, it will increase the
privacy duration by 15 minutes (starting from 0 up to a maximum of 20 hours i.e. pressing the button
8 times = 2 hours up to a maximum of 80 presses for 20 hours). Once the required privacy duration
has been reached, wait 3 seconds for the exit beep.To set the privacy with no time out Press and
hold “ ” (for approx 10 seconds) until the unit emits a beep do not press any other button, wait 3
seconds for the exit beep.
The new value is now stored.
RESTORE FACTORY DEFAULTS
Power up the intercom keeping pressed “
”;
The intercom will emit a beep to confirm the operation;
Release “
”.
TECHNICAL SPECIFICATION
Addressing range : from 1 to 180 (BIN code)
Working voltage : 12Vdc
Stand-by absorption : about 6mA
Phone max. absorption : about 50mA
Working temperature : -10 +50 C°