SENTRY1 TECHNICAL MANUAL VER1.6
TIME CLOCK Art.701
OPTIONAL ISOLATION PCB
BST/GMT digital time clock. This time clock operates from a 12Vac
or dc power supply. The output is a dry contact relay. When used
with the Sentry1 control system, the relay is used to short the time
clock inputs on the sentry1 PCB which will in turn enable the trade
button input to accept a short from a trade button. This will then
energise the lock relay on the Sentry1 PCB.
Connection Function
+ 12Vac or dc voltage input
- 0V
TR Not used with Sentry system
C Common connection on relay
NO Normally open connection on relay
NC Normally closed connection on relay
For more information see time clock instruction sheet
An isolation card will prevent a fault in a single
apartment affecting the rest of the system. The
isolation card has four channels (One card required
for every four apartments) and can be mounted in
the main control cabinet or in riser boxes.
Operation:
The isolation card will trigger an output when it
receives a positive voltage on either A, B, C or D.
The output will stay triggered as long as the SW+
terminal has 12 volts present. Once the 12V is
removed from the SW+ terminal the output will
switch back into isolated mode. The inputs A-D are
from the call buttons at the door panel and the SW+
is switched by the Sentry1 PCB (Terminal 3 of the
amp). Four LED’s on the PCB indicate when an
output is live.
2
1
4
4
4
4
Power and phone commons from Sentry
PCB
Select lines from call buttons
Call tone & +12V to phones fuse
Phone connections to apartment
Output live LED
1
2
3
4
5