SENTRY1 TECHNICAL MANUAL VER1.6
CONTROL CABINET
The control cabinet consists of three primary components plus optional extra components
such as line card isolation, door monitoring etc. The three primary components are the
Sentry 1 control PCB, power supply unit and time clock.
SENTRY 1 PCB
CONNECTIONS
CON Terminal Function
CN1 Vin 12Vdc input power
Vout 12Vdc output
GND Negative input
GND Negative output
CN2 NO1 Door 1 relay contacts 1
CO1 Door 1 relay contacts 1
NC1 Door 1 relay contacts 1
NO2 Door 1 relay contacts 2
CO2 Door 1 relay contacts 2
NC2 Door 1 relay contacts 2
CN3 NO1 Door 2 relay contacts 1
CO1 Door 2 relay contacts 1
NC1 Door 2 relay contacts 1
NO2 Door 2 relay contacts 2
CO2 Door 2 relay contacts 2
NC2 Door 2 relay contacts 2
CN4 12V ( + ) 12V supply to phones
7 ( - ) Negative supply to phones
5 ( P ) Lock trigger from phones
4 ( T ) Call tone to phones
2a ( 2 ) Receive speech to phones
1a ( 1 ) Transmit speech from phones
CN5 A Trigger from door 2
4 Negative supply to amp (door 2)
3 Switched 12V supply to amp (door 2)
2 Transmit speech (door 2)
1 Receive speech (door 2)
ENG Engaged output (high when call in progress)
CN6 A Trigger form door 1
4 Negative supply to amp (door 1)
3 Switched 12V supply to amp (door 1)
2 Transmit speech (door 1)
1 Receive speech (door 1)
CB Button commons
CN7 TC3 Time clock connection
TC3 Time clock connection
TC2 Trade button for door 2
TC2 Trade button for door 2
TC1 Trade button for door 1
TC1 Trade button for door 1
12Vdc input fuse (1amp)
Call tone fuse (315mA)
6 way dipswitch
System status LED’s
1
2
3
2
4
CN1
CN2
CN5
CN4
CN6
CN7
3
1
4
CN3
SW1 SW2 TIME
ON OFF 1 Second
OFF ON 2 Seconds
OFF OFF 4 Seconds
ON ON 8 Seconds
SENTRY 1 DIP-SWITCHES
CALL TONE TIME
SW3 SW4 TIME
ON OFF 16 Seconds
OFF ON 32 Seconds
OFF OFF 60 Seconds
ON ON 120 Seconds
CONVERSATION TIME
SW5 SW6 TIME
ON OFF 2 Seconds
OFF ON 8 Seconds
OFF OFF 16 Seconds
ON ON 40 Seconds
RELAY TIME