PAGE 18 of 29 SENTRY TECHNICAL MANUAL VER1.6
Safety Note : The earth wire from the cabinet lid should be connected to the cabinet base
and then to the earth connection in the building. This should be checked for continuity.
An earth connection should also be fitted to the door panel stainless steel facia using one
of the studs provided.
TESTING THE INSTALLATION
- Check all the connections have been made correctly and then power up the system.
- Call all the apartments in turn. Check for call tone to the apartment, speech in both
directions and lock release.
- If the volume of speech needs to be adjusted, this can be done by adjusting the presets
on the rear of the amplifier at the door panel as shown on page 3.
- If the call tone volume needs adjusting this can be done at each handset (Three
position slid switch on the telephone).
- Check the fireman switch (If fitted).
- Set the time clock on/off times (Use the instruction supplied with the time clock). Check
the trade button only works when the time clock is on.