PAGE 10 of 29 SENTRY TECHNICAL MANUAL VER1.6
APARTMENT STATIONS
500
The model 500 apartment station includes a push to talk button, door release button and
slide mute switch. The Intercom 3 PCB must be used when using this apartment station.
DIP SWITCH SETTINGS
8 Way dip switch (Switches 1 – 5)
Mute Duration time
Time 1 2 3 4 5
15 Minutes ON OFF OFF OFF OFF
30 Minutes OFF ON OFF OFF OFF
2 Hours OFF OFF ON OFF OFF
4 Hours OFF OFF OFF ON OFF
8 Hours OFF OFF OFF OFF ON
3 Way Dip Switch
VIDEO MODE continued
Switch
1 2 3
Coax OFF OFF OFF
Non-Coax ON ON ON
8 Way dip switch (Switch 6)
Mute LED
Switch
6
Fixed OFF
Flashing ON
8 Way dip switch (Switches 7 & 8)
°° Button Operation
Switch
7 8
Camera recall ON OFF
Dry contact OFF ON
4 Way Dip Switch (Switches 1 & 2)
S Button Operation
Switch
1 2
Camera recall ON OFF
Dry contact OFF ON
4 Way Dip Switch (Switches 3 & 4)
VIDEO MODE
Switch
3 4
Coax ON ON
Non-Coax OFF OFF
Connections:
Function
4 Select line from call button
2 Switched +12V to activate
6 Talk Button
1 Lock release button
3 Audio
5 Ground
Commenti su questo manuale